China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group Win-win together!

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Patient Monitor Parts /

UT4000C UT4000F Patient Monitor NIBP Board UT4000A UT4000B GW4F5S01C Bed Side Monitor Parts

Contact Now
China World Technology Medical Equipment Service Group
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MissKiara
Contact Now

UT4000C UT4000F Patient Monitor NIBP Board UT4000A UT4000B GW4F5S01C Bed Side Monitor Parts

Ask Latest Price
Video Channel
Brand Name :Goldway
Model Number :UT4000A UT4000B UT4000C UT4000F
MOQ :1
Payment Terms :T/T, Western Union,PayPal
Delivery Time :3-5 working days
Product name :Goldway
Type :UT4000A UT4000B UT4000C UT4000F
Product Name :NIBP board
Warranty :90days
Repeat Cycles :1~10, 15, 30, 60, 90, 120 minutes
Deflation Pressure :30mmHg(4.0kPa) higher than the last systolic pressure.
Cuff Inflation Rate :No greater than 50mmHg/sec
Mode of transport :Express delivery
Minimum purchase :1pcs
Pressure Display Accuracy :± 3mmHg
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Goldway UT4000A UT4000B UT4000C UT4000F patient monitor NIBP board GW4F5S01C


Brief Introduction

Processing the NIBP
Pressure data is converted to digital format and conveyed to the processor. The NIBP pump uses an oscillometric method that drives stepwise pressure deflation. Pump software eliminates most ambient noise and motion interference. It can be applied to neonatal, pediatric and adult patients. The blood pressure range for Systolic is 30-254 mmHg and Diastolic 10-220 mmHg. Accuracy is Maximum Mean Error ±5 mmHg, with Maximum Standard Deviation no greater than 8 mmHg.
NIBP processing uses an oscillometric technique to provide needed measurements at selected intervals. This technique uses an inflatable sPHiliphhilipygmomanometer cuff similar to those used by clinicians in routine measurements. A motorized pump inflates the cuff to approximately 170 mmHg (adult mode) initially, at which point the pressure effectively stops the flow of blood. Then, under monitor control, the pressure in the cuff is gradually reduced, while a pressure transducer detects the pressure and transmits the parameter signal to the NIBP input circuitry. As the pressure is reduced, blood flows in the previously occluded artery, and changes the measurements made by the transducer. The point at which oscillation increases sharply is defined as systolic pressure. As the cuff continues to deflate, the oscillation amplitude increases to a maximum, and then decreases. The peak oscillation amplitude is defined as the mean arterial pressure. The point at which the system detects a rapid decrease in oscillation is defined as the diastolic pressure.


The NIBP assembly and circuitry contain the following elements:
• Pump
• Valves
• Manifold
• Filter
• Pressure measurement and control circuitry

Non-Invasive Blood Pressure(NIBP)

Method Automatic Oscillometric
Parameters Systolic, diastolic, mean arterial pressure, pulse
Scale mmHg or Kpa
Operating Modes Manual, Automatic, Continuous
Repeat Cycles 1~10, 15, 30, 60, 90, 120 minutes
Measure Range Systolic Adult/Pediatric 30 ~ 254mmHg (4.0 ~ 33.9kPa)
    Neomate 30 ~ 135mmHg (4.0 ~ 18.0kPa)
  Diastolic Adult/Pediatric 10 ~ 220mmHg (1.3 ~ 29.3kPa)
    Neomate 10 ~ 110mmHg (1.3 ~ 14.7kPa)
Cuff Pressure Range Adult/Pediatric 0 ~ 280mmHg (0 ~ 37.3kPa)
  Neonate 0 ~ 140mmHg (0 ~ 18.7kPa)
Initial Cuff Inflation Adult/Pediatric 170 ± 10mmHg (22.7 ± 1.3kPa)
  Neonate 100 ± 10mmHg (16.0 ± 1.3kPa)
Deflation Pressure 30mmHg(4.0kPa) higher than the last systolic pressure.
Cuff Inflation Rate No greater than 50mmHg/sec
Measurement Time Typical 25 seconds
  Maximun 40 seconds
  Typical Stat 20 seconds
Pressure Display Accuracy ± 3mmHg  



Company Profile
As a medical equipment expert, we have many years of experience in the production and sales of medical equipment. Our products are of high quality and have always won unanimous praise from customers at home and abroad. We are proficient in medical equipment maintenance technology, and have always been at the forefront of developing the most advanced types of medical equipment and accessories to provide customers and society with the best quality services. We adhere to the concept of win-win cooperation and are committed to protecting the medical device market, providing perfect preferential prices, excellent quality, and reliable services.

.

Thank you for your time and interest. If you want to explore more details about Goldway UT4000A UT4000B UT4000C UT4000F patient monitor NIBP board GW4F5S01C, please let us know.

Inquiry Cart 0