2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP

Contact Now
China World Technology Medical Equipment Service Group
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MissKiara
Contact Now

2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP

Ask Latest Price
Video Channel
Brand Name :GE
Model Number :2060241-001
Certification :CE
MOQ :1pcs
Payment Terms :Full before shipment
Delivery Time :3-5 working days
Packaging Details :Carton
Product Name :2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP
Brand :GE
Part No :2060241-001
Monitor Parameters :ECG, O2 - SpO2, Blood Pressure - NIBP, Temperature
Condition :Excellent
MOQ :One piece
Delivery Method :DHL ,UPS ,Fedex
Payment Method :T/T ,Paypal ,Western Union
Application :Hospital Devices; Medical Care; ICU;
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP

Connection of ECG equipment to patient

(1) ECG connector

(2) Multi-Link 5-lead ECG trunk cable or 3-lead ECG cable

(3) 3 or 5 lead set

Note: For a complete list of accessories, see "Consumables and

The "Accessories" catalog comes with the monitor. Check

The expiry date of the ECG electrodes.

Note: Keep the ECG cable, lead set and module connector dry.

Avoid excessive use of liquids when cleaning cables and connectors.

Note: In a 5-lead ECG, place the fifth electrode (C/V) in one of the six electrodes

Indicate the place and select the corresponding V lead label.

Item name GE B20i patient monitor parameter module with IBP SPO2 ECG NIBP 2060241-001
Brand GE
Model GE B20i patient monitor parameter module with IBP SPO2 ECG NIBP 2060241-001
Use place Hospital Devices; Medical Care; ICU;
Deliver time 3-5 days
Warranty 90 days

Pulse oximetry (SpO2)

Measurement limits

− Pulse oximeter cannot distinguish oxygenated hemoglobin

And hemoglobin is abnormal.

− When using ear probes, poor perfusion may affect the accuracy of the measurement.

− To avoid false readings, do not use blood pressure cuffs or

An arterial blood pressure measuring device in the same limb as the sensor.

SpO2 configuration

The monitor has three SpO2 configuration options: GE TruSignal,

Massimo and Nelco. This setting will be pre-configured by the manufacturer according to your choice. Different settings may have different performance, please refer to "Technical Specifications"

more details.

Massimo

5,758,644,6,011,986,6,699,194,7,215,986,7,254,433,7,530,955 and

Other applicable patents

Nellcorrr

5,485,847; 5,676,141; 5,743,263; 6,035,223; 6,226,539; 6,411,833;

6,463,310; 6,591,123; 6,708,049; 7,016,715; 7,039,538; 7,120,479;

7,120,480; 7,142,142; 7,162,288; 7,190,985; 7,194,293; 7,209,774;

7,212,847; 7,400,919

SpO2 and patient connection

(1) Compatible SpO2 measurement capability

(2) Interconnect cable

(3) Reusable sensor

(4) Disposable sensor

Prepare the patient for SpO2 measurement

1. Connect the sensor to the blue connector in the display.

2. Clean the surface of the reusable sensor.

3. Clean the application area. Remove nail polish, artificial

Nails, earrings, etc.

4. Cut long nails.

5. Connect the sensor cable to your wrist or bedding to prevent

The cables and sensors move.

6. Check if the red light is in the sensor.

7. Check whether the waveform and parameter values ​​are displayed

When the probe is connected to the patient.

Note: Only use dry and clean sensors.

Note: Do not use blood pressure cuff or arterial sPHiliphhilipygmomanometer

A measuring device located on the same limb as the sensor.

Note: GE Healthcare sensors do not contain latex. Reference introduction

Each type of probe to ensure the materials used

The patient or any other person may come into contact with it.

Select SpO2 heart rate

Heart rate can come from many sources. show

Pulse rate measured by pulse oximeter:

1. Press the SpO2 key.

2. Select HR source-Pleth.

NOTE: Art, ABP, UAC is visible when a related label is selected.

Note: The AUTO selection priority for heart rate calculation is:

ECG (the lead with the highest R wave), pressure (Art, ABP, UAC), and

The plethysmograPHiliphhilipy pulse waveform.

Adjusting SpO2 pulse beep tone volume

You can adjust the volume of the beat sound:

1. Press the SpO2 key.

2. 2. Select Beat Sound Volume.

Non-invasive blood pressure (NIBP)

NIBP to patient connection

  • NIBP connector in monitor
  • Cuff hose
  • Cuff of correct size
  • Brachial artery arrow (printed on cuff)
  • Cuff index line (printed on cuff)

Invasive blood pressure

IBP equipment to patient connection

  • Compatible IBP measurement capability
  • Fluid bag or bottle with pressure infusor
  • Flushing set
  • Disposable catheter
  • Transducer
  • Adapter cable for the IBP transducer
  • Adapter cable for dual IBP measurement