P/N 01.21.064142-11 Edan Im60 Rechargeable Li Ion Battery 14.8V 2500mAh / 37Wh

Contact Now
China World Technology Medical Equipment Service Group
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MissKiara
Contact Now

P/N 01.21.064142-11 Edan Im60 Rechargeable Li Ion Battery 14.8V 2500mAh / 37Wh

Ask Latest Price
Video Channel
Brand Name :Edan
Model Number :01.21.064142-11
MOQ :1pcs
Payment Terms :T/T(wire transfer), Western Union, Paypal
Delivery Time :3-5 working days
Packaging Details :Carton
Product Name :P/N 01.21.064142-11 Edan Im60 Rechargeable Li-Ion Battery 14.8V 2500mAh/37Wh
Brand :Edan
Part NO :01.21.064142-11
Voltage :14.8V
Rated Capacity :2500mAh/37Wh
Limited Charge Voltage :16.8V
Warranty :90 days
Operating Time :2.1Ah 150 min or longer
Charge Time :2.1Ah 200 min or shorter
MOQ :One piece
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

P/N 01.21.064142-11 Edan Im60 Rechargeable Li-Ion Battery 14.8V 2500mAh/37Wh

Battery Status displays the detected status of each battery and the remaining combined battery charge, as well as the estimated monitoring time. There is a sign indicating the charging status in the lower left corner of the screen, and the yellow part is the power of the battery. When the monitor is not equipped with a battery, the battery status will be displayed as a symbol indicating no battery. When the monitor is powered by batteries, the monitor will automatically shut down if there is no power in the battery. When the power is low, a sign will be displayed on the screen. When the monitor is powered by batteries, the monitor will automatically turn off if there is no power.

Checking Battery Performance

Battery performance can degrade over time. The battery care recommended here can help slow this process down.

1. Disconnect the patient from the monitor and stop all controls and measurements.

2. Turn on the monitor and charge continuously for more than 6 hours.

3. Unplug the monitor power cord and leave it on until the battery dies and the monitor turns off.

4. Battery life reflects battery performance. If the usage time is significantly less than the time specified in the manual, replace the battery or call customer service.

Warning

1. Before using the rechargeable Li-ion battery (hereinafter referred to as the battery) Please read the user manual and safety information carefully.

2. Do not connect the positive (+) and negative (-) terminals with metal objects. And do not place the battery on metal objects, otherwise it may cause a short circuit.

3. Do not remove the battery during the inspection.

4. Do not heat or throw the battery into fire.

5. Do not use batteries. Do not place it near fire or other places. where the temperature may be higher than 60℃

6. Do not immerse, drop or wet the battery in water/seawater.

7. Do not damage the battery: Do not puncture the battery with sharp objects such as needles. Do not hit with a hammer, step on, throw, or drop it to cause severe vibration. Do not disassemble or modify the battery.

8. Use only the battery in the monitor. Do not connect the battery directly to the cigarette lighter socket or charger.

9. Do not solder wires and battery terminals directly.

10. If the battery leaks into the eyes, do not rub the eyes, rinse with clean water and consult a doctor immediately. If battery liquid gets on your skin or clothing Wash immediately and thoroughly with clean water.

11. As soon as a leak or smell is detected Immediately move away from the fire source.

12. If heat, odor, discoloration, deformation or abnormal conditions are detected during use, charging or storage stop using the battery Keep away from the monitor

13. Do not use batteries that are scratched or deformed.

Specification

Operating Time 2.1Ah 150 min or longer
4.2Ah 300 min or longer
Condition At 25°C, with (a) new fully charged battery/batteries, continuous SpO2 measurement and NIBP automatic measurement mode at interval of 15 minutes, ECG/TEMP module connected, recording at interval of 10 minutes, brightness set to “1”
Charge Time 2.1Ah 200 min or shorter
4.2Ah 360 min or shorter
Condition Monitor is on or in standby mode.
Voltage 14.8V
Rated Capacity 2500mAh/37Wh
Limited Charge Voltage 16.8V

Replacing the Battery

1. Pull the battery compartment open as shown.

2. Pull the plastic latch until the battery can be removed.

3. Insert the new battery into the battery compartment.

4. Lower the metal latch to secure the battery and close the battery door.

Battery recycling

When the battery is no longer charged, it must be replaced. Remove old batteries from the monitor and recycle properly.

Note: In order to extend the battery life, it is recommended to charge it at least once a month, after the end of the power supply.