Hospital Medical Equipment Used Nihon kohden Cardiolife TEC-7721C Defibrillator
► Brief Introduction
Nihon kohden TEC-7721C defibrillator provides low energy biPHiliphhilipasic waveform defibrillation. BiPHiliphhilipasic waveform defibrillation requires lower energy than conventional monoPHiliphhilipasic defibrillation and causes less damage to myocardium.
BiPHiliphhilipasic technology demonstrates superior results to save the patient from sudden cardiac arrest. Nihon Kohden’s unique ActiBiPHiliphhilipasic* technology provides an improvement over most conventional biPHiliphhilipasic circuits by employing an original T-circuit. In conventional biPHiliphhilipasic circuits, when impedance is high, pulse width becomes wider which reduces the efficiency of defibrillation. Nihon Kohden’s T-circuit actively controls the shape of the second PHiliphhilipase waveform to maintain constant pulse width.
► Description
11. Recording Lamp
12. Event Key
13. Event Lamp
14. ECG Lead Key
15. ECG Sensitivity Key
16. SILENCE ALARM Key
17. Alarm Setting Key
18. AC Lamp
19. Battery Charging Lamp
20. Battery Charge Complete lamp
► AED with optional voice prompt
AED (Automated External Defibrillation) is available with disposable pad adaptor cable (option) and disposable pads. When shockable rhythm is detected, TEC-7600K/7700K automatically starts charging for hands-free defibrillation. CPR timing sound is also provided. Voice prompt is optionally available for less frequent users.
► Functions
External Paddles | Standard |
Internal Paddles | Option |
Disposable Pads | Option |
Pediatric electrode assy 44 mm dia. | Option |
3 lead ECG | Standard |
AED Function | Standard |
Noninvasive Pacing | Not Available |
SpO2 Measurement | Option |
CO2 Measurement | Option |
Voice Prompt | Option |
5 Lead ECG | Option |
External ECG Input | Option |
External ECG Output | Option |
Memory Card Slot | Standard |
NIBP Measurement | Option |
12 Lead ECG Measurement | Option |
Transmitter | Option |
► Features
• Protection from sudden capacitor failure
The high voltage capacitor is divided into thousands of individual cells to prevent sudden, total failure of the capacitor. If any part fails, the remaining cells can still provide shock. The high-voltage capacitor is automatically tested by a capacitor test program which measures the capacitance by charging and discharging.
• Reliable battery operation
An optional NiMH (nickel metal hydride) rechargeable battery provides reliable battery operation. A new real load testing method indicates the actual remaining charge so you can know approximately how many defibrillations are available. Battery performance test is done by simulating actual charging and discharging to accurately test the quality of the rechargeable battery.
• Easy routine checking
You can easily check the instrument at any time.
If you are interested in Hospital Medical Equipment Used Nihon Kohden Cardiolife TEC-7721C Defibrillator , welcome to place your orders.