China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group Win-win together!

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Patient Monitor Module /

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

Contact Now
China World Technology Medical Equipment Service Group
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MissKiara
Contact Now

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

Ask Latest Price
Video Channel
Brand Name :PHiliph Goldway
Model Number :865492
MOQ :1pcs
Payment Terms :Full before shipment
Delivery Time :3-5 working days
Packaging Details :Carton
Product Name :PHiliph Goldway Part No 865492 Multiparameter Module For G60 Modular Patient Monitor
Brand :PHiliph Goldway
Use for :G60 patient monitor
Part No :865492
Use place :Hospital Devices; Medical Care; ICU;
Warranty :90 days
Delivery Method :DHL,UPS ,Fedex ,etc
Payment method :T/T ,Paypal ,western union
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

PHiliphh Goldway Part No 865492 Multiparameter Module For G60 Modular Patient Monitor

To perform a multi-parameter block connection test:

1. Insert the module into the G60 Modular Patient Monitor module slot or Flexible Modular Server (FMS).

2. Turn on the monitor.

3. Check the module light.

If lit:

On = Module is properly connected.

Not lit = Module is not connected properly.

(See the yellow rectangle in the picture below)

4. Press the main menu button and check that the display shows the main menu. (See the picture in the green rectangle below.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

Product Name

PHiliphh part no 865492 Multiparameter module for G60 Modular Patient Monitor

Brand PHiliphh Goldway
Part No 865492
Use for G60 patient monitor
Use place Hospital Devices; Medical Care; ICU;
Warranty 90 days
Delivery Time 3-5 working days

In addition to the basic parameters, the multi-parameter module (MPM) has optional parameters: IBP1/IBP2 and 12 lead ECG. The following disassembly procedure applies to both MPMs.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

Note :For the multi-parameter module with 12 lead ECG function, a symbole ( PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor) will be printed on the left conner of the multi-parameter module.

Remove the Rear Case

  • Use a utility knife or flat-blade screwdriver to remove the two white plastic nuts on the back

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Remove the two M3X8 screws and washers.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Use the modular rivet wrench to remove the two rivets

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Carefully invert the MPM on a soft surface. Use a flat-blade screwdriver to pry off one end of the module rail

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Insert a second flat-blade screwdriver into the slot on the bottom

of the module rail to release the rail latch as shown.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Slide the module rails in the direction shown in the figure and remove the rails.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Repeat steps 4 through 6 above to remove the second module rail. Remove the two M3x4 screws shown

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Remove the rear case.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

Separate Main Frame and Front Panel Assembly

  • Remove the cable and two M3x6 screws from the right side of the front panel

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Remove the two M3X6 screws on the left side of the front panel.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Carefully remove the main body and screen assembly

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Disconnect the SpO2 connector cable, the NIBP / TEMP connector cable (on the front panel), and the NIBP connector tube.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Remove the main body and front panel

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

Remove the ECG Board

  • Remove the four M3X6 screws

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Gently pull up the ECG board and remove the NIBP/TEMP connector cable (to ECG board).

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Remove the ECG board.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

Remove the SpO2 Board

  • Remove the SpO2 connector cable

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Remove the two white plastic M3X6 screws.

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor

  • Gently pull up the SpO2 board and remove it. Note the orientation of the board using the circled connector shown

PHiliph Goldway 865492 Multiparameter Module For G60 Modular Patient Monitor