Mindray M7 Ultrasound Rechargeable Li-Ion Battery Pack L1231001A
The battery charges when the system is connected to AC power
A fully depleted battery typically fully recharges in 2-3 hours if the system is turned off; or the battery has been normally charged for 2 hours (the system is off).
When not connected to an external power source, it runs on two lithium-ion batteries.
The rechargeable Li-ion battery (hereafter: battery) is LI23I001A.
Remarks:
1. Use only specified items.
2. If there is only one battery in the system, it cannot supply power and cannot be charged.
3. Replace both batteries at the same time.
4. If the battery is not used for a long time, charge it regularly. Otherwise, battery performance will deteriorate.
Caution
1. Before using the battery, carefully read the instructions on the label affixed to the surface of the battery.
2. When you use the battery for the first time, if you find the battery dirty or smelly, please don't use it.
3. Do not expose the battery to heat or high voltage.
4. Do not expose the battery to direct sunlight.
5. Keep the battery out of reach of children.
6. The battery is designed to be charged only in this system; charge the battery only when the ambient temperature is between 0 and 40°C.
7. If the battery is low, charge it immediately.
8. If stored for more than three months, charge the battery up to 45%.
9. Don't hit the battery
Specification
Capacity | 4500mAh |
Weight | 330g |
Color | light gray |
Voltage | 11.1v |
Installing and Removing the Batteries
The battery is located in the battery compartment under the bottom of the system. It requires two elements.
You can install or remove them when the system is off and the adapter is disconnected from the host.
Inserting the battery:
1. Turn off the system and disconnect the host adapter.
2. Turn off the monitor, turn the system upside down, and place it on the table.
3. There are two battery slots at the bottom of the system (note that the battery
it must be placed in the correct direction; otherwise, the battery will not fit). Gently press down on the battery until it clicks into place. The battery is now in the bay.
To remove the battery:
1. Turn off the system and disconnect the host adapter.
2. Turn off the monitor, turn the system upside down, and place it on the table.
3. Press the loop between the two brackets to open the battery.
4. Remove the battery from the compartment
battery status indicator
The battery status indicator is located in the lower right corner of the screen and indicates the battery capacity.
If the battery is low, the system displays the following message:
"Warning! The battery is low! Plug in the adapter or the system will shut down in a minute." Plug in the power supply and it will work.
Check the battery performance
Battery performance may decline over time, so check battery performance regularly. The verification procedure is as follows:
1. Stop the ultrasound.
2. Connect the system to AC power to charge the battery until it is fully charged.
3. Disconnect the system from AC power and run it on battery until it automatically shuts down.
4. Battery on time indicates battery performance.
If the battery operating time is much shorter than specified, you can replace the battery or contact the service center.