GE RIC5-9W-RS Ultrasound Transducer Probe
GE RIC5-9W-RS 3D4D Intracavitary Ultrasound Transducer Probe for GE Voluson i; Voluson e; Voluson S6; Voluson S8
► Brief Description
GE RIC5-9W-RS 3D4D Intracavitary Ultrasound Transducer Probe
GE RIC5-9W-RS Ultrasound Transducer Probe - The main function of this intracavitary ultrasound probe is to help medical professionals observe and diagnose the internal structures and conditions of the human body by sending ultrasound waves into the body and receiving the reflected sound waves and converting them into images.
It is a used but fully functional product, which has been professionally tested by engineers to ensure its usability. You can contact us for more details before placing an order.
We also accept probe repairs. If your probe is faulty and needs to be repaired, please contact us to learn how to repair it.
► Specification
Brand | GE |
Product Category | Ultrasound |
Product Type | Transducer / Probe |
Model Number | RIC5-9W-RS |
Frequency Range | 5-9MHz. |
Probe Type | Micro-Convex Array |
Applications | Obstetrics and gynecology, urology, etc. |
Imaging | 2D, 3D, 4D |
Machine Application | Voluson i; Voluson e; Voluson S6; Voluson S8, etc. |
Condition | Used with Good Condition |
Warranty | 90 Days |
Payment Method | Western Union, Bank T/T, Paypal |
Minimum Order Quantity | 1 |
► Detailed Photos
► Maintenance
Use and maintenance:
- Follow the relevant operating instructions and equipment requirements to correctly connect and operate the probe.
- Clean and disinfect as required after use to prevent cross infection.
- Handle with care to avoid severe impact or damage to the probe.
- Check the appearance and performance of the probe regularly to ensure that it is working properly.
- Store in an appropriate environment to avoid factors that may affect its performance, such as high temperature, humidity, and strong magnetic fields.
► Operation
I. Preparation
1. Make sure the ultrasound device is properly turned on and in normal working condition.
2. Check whether the probe is clean and undamaged, and whether the cable is intact.
II. Probe connection
1. Find the corresponding probe interface on the ultrasound device.
2. Insert the probe plug carefully and accurately into the interface to ensure a firm connection.
III. Patient preparation
1. According to the examination site and purpose, let the patient take the appropriate position.
2. Apply an appropriate amount of coupling agent on the probe surface to ensure good ultrasound transmission.
IV. Operation
1. Hold the probe and slowly and gently insert the probe into the patient's body to the appropriate position.
2. Select the corresponding probe mode (such as 3D/4D mode) and examination parameters on the operation interface of the ultrasound device.
3. Move the probe to obtain the image of the required part, paying attention to maintaining stable contact and appropriate angles.
V. Image Adjustment
1. Adjust the image gain, depth, focus and other parameters as needed to obtain a clear and accurate image.
2. Use zoom, rotation and other functions to further observe and analyze the image.
VI. End of Examination
1. Slowly and gently remove the probe from the patient.
2. Clean the probe to remove coupling agent and possible contaminants.
Thanks for your interest in GE RIC5-9W-RS 3D4D Intracavitary Ultrasound Transducer Probe for GE Voluson i; Voluson e; Voluson S6; Voluson S8, please feel free to contact me. Thank you for your time and wish you have a happy life.