► About Nihon Kohden BSM-2301C Patient Monitor Analog Board UR-3612 36121 6190-024226A
The analog board consists of ECG/RESP block, SpO2 block, MP block, and ZB900P interface block. The ECG/RESP block, SpO2 block, and MP
block are electrically isolated from ground, so these blocks are placed in the floating zone. The ZB-900P interface block is not electrically isolated
from ground, so it is placed in the non-floating area. The vital signs input signal is digitized by the A/D converter in the floating area, as shown
below. In particular, processing such as calculating SpO2 data is completed in the floating area, and the SpO2 data is sent to the DPU on the
main board through the non-floating area.
► Replacing the Analog Board
1. Remove the 3 screws (marked with circles in the following picture) which secure the Analog board to the chassis block.
NOTE :
If the 3 screws are left in the holes, it may be difficult to slide the Analog board
2.Slide the Analog board in the direction of the arrow in the picture below to avoid obstruction of the ZB socket and remove the Analog board from
the chassis block. In case of BSM-2303/2304/2353/2354, Disconnect the connection cable which connects between the Analog board and IBP
board.
► Specification of Nihon Kohden BSM-2301C Patient Monitor Analog Board UR-3612 36121 6190-024226A
Product Name | Nihon Kohden BSM-2301C Patient Monitor Analog Board UR-3612 36121 6190-024226A |
Brand | Nihon Kohden |
Application | Nihon Kohden BSM-2301C Patient Monitor |
MOQ | One piece |
Warranty | 90 days |
Condition | Used |
Color | Green |
Material | Plastic |
Part No | UR-3612 36121 6190-024226A
|
► CWT TECHNOLOGY HK Limited packaging
In order to ensure that customers receive satisfactory products, engineers will repeatedly test the performance of the products before shipment to
ensure that the products can work properly. After the test, product pictures or videos will be sent to customers for confirmation. Because it is
second-hand, the product will inevitably have traces of use, or some yellowing, which is normal. If you have strict requirements on appearance,
please purchase with caution. Of course, in order to make the appearance of the product look more beautiful, clean and comfortable, we generally
clean the shell and handle before shipment. For some circuit boards, we will use anti-static bags for packaging, and use bubble paper for
packaging, and do a good job of shockproof treatment of the product to prevent damage during transportation. Of course, because medical
products are special, we will take rainproof measures outside the box to prevent the product from getting wet and unusable.
Thank you so much for your attention .If you're interested in Nihon Kohden BSM-2301C Patient Monitor Analog Board UR-3612 36121 6190-024226A ,feel free to contact us .Thank you .