China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group Win-win together!

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Medical Lighting /

Shanghai Excellence Kehua KHB420 12V 20W ZY800 ZY1200 Fully Automatic Biochemical Analyzer Light Source Bulb

Contact Now
China World Technology Medical Equipment Service Group
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MissKiara
Contact Now

Shanghai Excellence Kehua KHB420 12V 20W ZY800 ZY1200 Fully Automatic Biochemical Analyzer Light Source Bulb

Ask Latest Price
Brand Name :Shanghai
Model Number :Excellence Kehua KHB420 12V 20W ZY800 ZY1200 fully automatic biochemical analyzer light source bulb
Certification :CE/CB/ROSH
MOQ :1
Price :USD
Payment Terms :L/C, D/A, D/P, T/T
Packaging Details :Carton
Brand :Shanghai
Color :Metal and glass
Category :Bulb
Wattanty :90 Days
Packing weight :1kg
size :Uniform size
Application area :Hospitals, private clinics, etc
Condition :new
Estimated Ship Time :3-5 Business Days
In stock :Enough stock
Specification :0.5x0.5cm
Used for :fully automatic biochemical analyzer light source bulb
net weight :0.5 kg
Shape :standard
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Shanghai Excellence Kehua KHB420 12V 20W ZY800 ZY1200 fully automatic biochemical analyzer light source bulb

►Quick Detail:

Excellence Kehua KHB420 12V 20W ZY800 ZY1200 fully automatic biochemical analyzer light source bulb
The light source bulb is the light source bulb of a fully automatic biochemical analyzer. The general process of light transmission is as follows: the composite light emitted by the bulb (12V, 20W placed inside the heat sink) is focused together by a condenser lens (maximizing the use of light source energy), the incident light is converted into parallel light by a collimator lens, and then enters the grating through a slit (to avoid stray light entering). The grating decomposes the composite light into multiple monochromatic lights, reflects them onto a filter (absorbs each monochromatic light), and then sends them to a detector (a column of light-emitting diodes) for photoelectric conversion. Finally, the signal is transmitted to the display screen through a signal processing board for analysis, calculation, amplification, etc.

Shanghai Excellence Kehua KHB420 12V 20W ZY800 ZY1200 Fully Automatic Biochemical Analyzer Light Source Bulb

How to determine the malfunction of a light bulb:

If the fully automatic biochemical analyzer around you shows an alarm message of "abnormal light bulb energy", you can immediately think that the light bulb may be old and needs to be replaced. However, considering that the fully automatic biochemical analyzer is a relatively large and precise instrument.
You need to find a light bulb of the same model as the automatic biochemical analyzer you have on hand for purchase and replacement.
Before replacing the light bulb, you need to click on "Maintenance" ->"Replace Light Bulb" to enter the maintenance interface, which displays values for 16 wavelengths. From here, you can see the deviation of the values after replacing the light bulb. Generally, the new device value should be above 1.0, and the old device value can also be above 0.7. After replacing the light bulb using this method, it was found that the values of wavelengths 340 and 578 were incorrect. Wavelength 340 corresponds to a value of 0.36, while wavelength 578 corresponds to a value of 0.5, both of which are lower than the standard value of 0.7 mentioned above. Clicking on the alarm option above still shows an "abnormal energy of the light bulb" alarm. After replacing the light bulb, click on the light bulb maintenance interface to check if the device prompts normal operation. If all displays are normal, it indicates that the bulb replacement is reasonable.

Key features:

Type: Shanghai Excellence Kehua KHB420 12V 20W ZY800 ZY1200 fully automatic biochemical analyzer light source bulb
Warranty period: 90 Days
Shipping Date: 3-5 Working Days
MODLE: KHB420 12V 20W ZY800 ZY1200
Storage temperature: -20-70°c
MOQ: 1 PCS
COLOR: Metal and glass
Delivery Date: 3 - 5 Working Days
Package Carton

► Company situation:

The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.

About delivery:

We default to express delivery by DHL,Fedex, We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.


Inquiry Cart 0