Mindray PM-9000 Patient Monitor
Mindray PM-9000 Patient Monitor Used-good Whole Machine Medical Equipment for Hospital,Clinc,etc.
► Brief Description
The main functions of the monitor include parameter measurement, waveform monitoring, freezing, recording and other functions. The monitor is designed with small size and light weight, which is very suitable for use in medical environments.
It is equipped with a color TFT LCD screen that can clearly display patient parameters and waveforms. It is also equipped with a handle for easy transportation and a built-in battery. It is also designed with a compact control panel and control knob for medical staff to freeze, record or perform other operations, as well as an easy-to-use menu system.
►Intended Use
This patient monitor can be adapted to a variety of environments/situations, including but not limited to ICU, CCU, cardiac ICU, operating room, emergency room, postoperative observation ward, etc.
It is worth mentioning that this monitor can also be used in hospital transfer or ambulance.
However, it should be noted that this patient monitor is not suitable for helicopter transfer or home use, so please pay attention to the occasion when using it.
► Major Parts and Keys
Front Panel
Side Panel
1. CO2 | CO2 sensor connector (Welch Allyn CO2 module) |
2. T1 | Temperature probe connector (channel 1) |
3. T2 | Temperature probe connector (channel 2) |
4. IBP1 | IBP transducer connector (channel 1) |
5. IBP2 | IBP transducer connector (channel 2) |
6. ECG | ECG cable connector |
7. CO | CO cable connector |
8. NIBP | NIBP cuff hose connector |
9. SpO2 | SpO2 sensor connecto |
10. | Battery door |
On the right side of the display you will find the connectors for connecting an Oridion or Mindray CO2 module or an AG module. The recorder is located at the bottom right side.
►Inspection
Follow these guidelines when inspecting the equipment:
A.Inspect the keys, control knob, connectors and accessories for damage.
B.The audible and visual alarms functions normally
C.The recorder functions normally and the recorder paper meets the requirement.
D.The environment and the power supply meet the specified requirements.
E.The grounding cables are correctly connected.
F..Only specified accessories like electrodes, sensors and probes are applied.
G.The monitor clock is correct
H.Inspect the power cords for fraying or other damage and check the insulation.
The synchronization function of the defibrillator must be verified according to your hospital's regulations and checked every 3 months by a qualified technician.
Do not use the monitor if there is any damage or abnormality. Please contact your hospital's technician or our customer service department immediately.
►Note
1. Always dilute the solution according to the manufacturer's recommendations and use the lowest concentration possible;
2.Never permit high-pressure and high-temperature disinfection of the equipment and accessories;
3.Never submerge the equipment into water or any solution, or pour water or any solution on the equipment;
4.Do not use EtO or formaldehyde for disinfection;
5.Wipe off any excess liquid on the surface of the device and accessories with a damp wipe.