GE B20 Patient Monitor NIBP Module Assembly 2047658-001 Parts for Blood Pressure Measurement
■ Product describe
The NIBP module of the GE B20 patient monitor is the core component of non-invasive blood pressure monitoring. The part number is 2047658-001. This component is designed for medical environments and its performance and materials meet the standards for use of medical devices. It can measure systolic, diastolic and mean arterial pressure (MAP) for adults, children and newborns of different ages and body types.
■ Features
1. Non-invasive blood pressure measurement
This accessory can automatically measure systolic, diastolic and mean arterial pressure (MAP) for adults, children and neonates using oscillation technology. By inflating the cuff to apply pressure to the artery, the pressure changes in the cuff are analyzed by combining algorithms to accurately identify the characteristics of the blood pressure waveform.
2. Intelligent pressure control
The "intelligent cuff" pressure control optimizes the measurement process, reduces the inflation time (the measurement can be completed in 10 seconds at the fastest), and improves the ability to resist motion interference to ensure data accuracy.
3. Multi-mode support
Manual mode: trigger a single measurement on demand.
Automatic mode: The interval measurement time can be set arbitrarily according to needs (such as once every 5-60 minutes), which is suitable for long-term monitoring.
Continuous mode: Continuously monitor blood pressure trends in scenarios such as surgery or transportation.
4. Safety protection mechanism
Built-in overpressure protection, leak detection and cuff adaptation reminder functions. When the cuff size is not suitable or the gas path is abnormal, the module will automatically alarm and terminate the measurement to avoid patient discomfort or equipment damage.
■ Product Pictures
■ Product Specification
Product Name | NIBP Module Assembly |
Part Number | 2047658-001 |
Condition | Used-Good |
Warranty | 90 Days |
Color | White |
Payment | TT/Paypal/Western Union |
Weight | Light |
Size | Small |
Shipping By | DHL or FedEx and etc. |
MOQ | 1 Piece |
■ FAQ
Q: What should I do if the NIBP measurement value is too high or too low?
A: Follow the steps below to troubleshoot possible causes:
Check the cuff: Confirm that the cuff is the correct size and fits the upper arm (the lower edge of the cuff is 2-3cm from the elbow), avoid being too loose or too tight.
Calibrate the module: Enter the "NIBP Calibration" function through the monitor menu and use a standard pressure source to verify the accuracy of the module.
Check the gas path: Check whether the hose is bent or leaking, and replace the spare cuff if necessary.
Q: Can this module be used in neonatal patients?
A: Yes. The module supports neonatal mode and needs to be paired with a special neonatal cuff, and select the "neonatal" patient type in the monitor menu.
Q: How to clean and disinfect the NIBP module?
A: For daily cleaning, you can use a microfiber cloth to wipe the surface of the module to prevent liquid from seeping into the interface.
If you need any medical equipment and accessories, please contact us.